Chromatotec expert in gaz analysis

Products

Markets

bullet point

Ambient Air Monitoring (outdoor)

bullet point

Industrial air monitoring (indoor)

bullet point

Pure gases / Gas Manufacturers

bullet point

Natural gases / LPG

bullet point

Emission and CEM

bullet point

Process

Exhibitions

bullet point

POLLUTEC 2010 - France 
Lyon Eurexpo (30 nov. - 3 dec. 2010)

bullet point

Journées Information Eaux 2010 
ENSI Poitiers (28 - 30 Sept. 2010)

bullet point

A&WMA 2010 - ALBERTA, CANADA 
Calgary Telus Convention Centre (22 - 25 June 2010)

bullet point

ACHEMASIA 2010 - CHINA 
Beijing (01 - 04 June 2010)

bullet point

NATURAL GAS ODORIZATION - USA 
Marriott Westchase Hotel Houston, Texas (25 - 26 May, 2010)

bullet point

LES RENDEZ VOUS CARNOT - France 
Espace double mixte - Lyon (5 - 6 May 2010)

bullet point

IRAN OIL SHOW - Iran 
Tehran Permanent Fairground - Tehran (22 - 25 April 2010)

bullet point

ENVIRO ARABIA - Kingdom of Bahrain 
Gulf International Convention & Exhibition Centre - Manama (18 - 21 April 2010)

Conferences & Posters

bullet point

ENVIRO ARABIA - Kingdom of Bahrain 
(18 - 21 April 2010)

bullet point

CERTECH - Symposium Emissions and odours from materials - Belgium 
(7 - 8 October 2009)

Automation module

 

The Automation module permits user defined automated computation. For example: Average computations, specific historical files, Logging files, alarm computation…

Objective
Automatic multiple compound average value computation of H2S ; RSH ; THT ; Total sulphur compounds and Odorization factor.

General
Analysis results are set in a Real Time DataBase (RTDB).
The Math Module gathers these results with previous one, computes if necessary the averages values and other alarm triggering. All these data are also set in another place of the RTDB.
The Modbus Driver continuously collects the data it needs from the RTDB and make them available to DCS or SCADA with Modbus protocol.
To test the communication, the Modbus client requests need to be setup in the host DCS or PLC.
The monthly historical files gather all substance results to be archive in CSV format which could be easily imported in a spreadsheet or a database.
The calibration standard DMS results could be log on request in a monthly separated file.

Alarm computing
All alarm computing is performed at every result release.
All alarm can be acknowledged from Vistachrom suite.
All alarm thresholds are gathered into a dedicated .ini file.
All alarm status changes are time stamped and logged into a monthly text file.

Security handling
Follow up of the calibration substance :
⇒ A deviation alarm against its target value is computed.
⇒ The target value is calculated after each calibration performed during the analyzer metrological follow up.

Hardware fault handling :
⇒ The Math module watch for all error reported by the analyzer, check if it is a valid error and trigger a specific hardware alarm.
⇒ The alarm is trigged if the analyzer doesn’t deliver some result before a predefined delay.

Software fault handling :
⇒ Every Vistachrom suite runtime program generates a life signal in the RTDB that could be reported to external DCS with the modbus driver. These life signals testify the full working of each softwares.
⇒ All hardware and software alarms are time stamped and logged in a monthly system text log file.