Exhibitions

BTEX and VOC

BTEX and VOC
This market is driven by law and legislations made in Europe and/or USA (US EPA). It deals with ambient air monitoring: analysis / calibration / automatic zero air in continuous 7 days a week.

Ambient air monitoring : in France this service is controlled by associations that calculate the ATMO index.

CHROMATOTEC instruments such as the BTX ,the Sulfur and the VOC analysers can be a good complement of their analysers such as O3, CO2, DUST… in the analysis of ambient air.

1) BTEX = airmoBTX FID or airTOXIC PID
 Options : 1.3 Butadiene or Styrene
Monitoring of: in urban, peripheral areas or on mountains, islands or boats in the ppt range.
TÜV norm on VOC (BTEX) for FID and CNR for PID


2) Ozone precursors = airmOzone PAMS ( 30 or 58 compounds) = airmoVOC C2-C + airmoVOC C6- C12 .
  airmoVOC C10-C18 (heavy compounds)
Calibrated with a cylinder: 58 PAMS 100 ppb at +/-1% and calculation of response factors related to Benzene.

3) CH4 / NMTHC / CO / CO2 = chromaTHC or chromaCO or airmoH-CHO.
 Also Acetone and/or Formaldehyde
Back to previous page

BTEX and VOC download

nothing to display Case Study airTOXIC PID Case Study airTOXIC PID (242.4 kb) Case study airmOzone Case study airmOzone (863.5 kb) Comparative study of automatic BTEX analyzers Comparative study of automatic BTEX analyzers (1.5 Mb) US EPA report US EPA report (428.4 kb)

Related Product :

  • airTOXICBTXPID

    A GC/PID for automatic monitoring of BTEX in air, water and soils
  • airmo BTX 1000

    A GC/FID instrument for BTEX monitoring in air, water and soil
  • airmoVOC C2C6

    Designed for analysis + monitoring of “light” hydrocarbons. It is used for the measurement of volatile hydrocarbon in the range of C2 to C6 i.e. from Ethane through 1,3-Butadiene up to Benzene (...)
  • airmo VOC C6C12

    Capable of anlaysing up to 32 compounds from C6-C12 (used in airmozone) or PAMS
  • CHROMA THC ppm

    Monitoring and analysis of Methane and Non-Methane Hydrocarbons (NMTHC) by flame ionisation detection (ppm level analysis)
  • CHROMA THC ppb

    CH4 and Non Methane Total HydroCarbon (NMTHC) Monitoring and analysis of Methane and Non-Methane Hydrocarbons by flame ionisation detection (ppm level (...)
  • CHROMA CO

    A gas analyser using flame detection with a catalytic methaniser module to analyse CO and CO2 for monitoring gas purity and electronic gas measurement. A 19" inch rack mountable chassis, 4U (...)
  • airmOzone cabinet

    Analysis of the Ozone precursor VOC
  • airmoC10C20

    Is able to analyze up to 16 PAH compounds or hydrocarbons Poly Aromatic Hydrocarbon