Continuous analysis of sulfur compounds in waste water

Continuous analysis of sulfur compounds in waste water

Analysis with the chromaS of sulfur compounds before and after a deodorization installation by chemical cleaning
Selective analysis of : H2S, CH3SH, C2H5SH, DMS, DMDS, CS2 :

 

Sulfur pollutants to be treated Maximum concentrations inlet (mg/m3) Average concentrations inlet (mg/m3) Guaranties outlet (mg/m3)
H2S 10 2 0,07
R-SH 1,5 0,5 0,04
Total sulfur 12 2,5 0,12

There are numerous interests to this continuous analysis, which mainly resides at various steps of this installation comissionning :

  • Process optimization
  • Yield calculation
  • Sulfur compounds speciation
  • Reception of the installation and performances test
  • Rapid analysis : 10 mn cycle time

 