Chromatotec expert in gaz analysis

Markets

bullet point

Ambient Air Monitoring (outdoor)

bullet point

Industrial air monitoring (indoor)

bullet point

Pure gases / Gas Manufacturers

bullet point

Natural gases / LPG

bullet point

Emission and CEM

bullet point

Process

Exhibitions

bullet point

POLLUTEC 2010 - France 
Lyon Eurexpo (30 nov. - 3 dec. 2010)

bullet point

Journées Information Eaux 2010 
ENSI Poitiers (28 - 30 Sept. 2010)

bullet point

A&WMA 2010 - ALBERTA, CANADA 
Calgary Telus Convention Centre (22 - 25 June 2010)

bullet point

ACHEMASIA 2010 - CHINA 
Beijing (01 - 04 June 2010)

bullet point

NATURAL GAS ODORIZATION - USA 
Marriott Westchase Hotel Houston, Texas (25 - 26 May, 2010)

bullet point

LES RENDEZ VOUS CARNOT - France 
Espace double mixte - Lyon (5 - 6 May 2010)

bullet point

IRAN OIL SHOW - Iran 
Tehran Permanent Fairground - Tehran (22 - 25 April 2010)

bullet point

ENVIRO ARABIA - Kingdom of Bahrain 
Gulf International Convention & Exhibition Centre - Manama (18 - 21 April 2010)

Conferences & Posters

bullet point

ENVIRO ARABIA - Kingdom of Bahrain 
(18 - 21 April 2010)

bullet point

CERTECH - Symposium Emissions and odours from materials - Belgium 
(7 - 8 October 2009)

New instrument for measurement of formaldehyde : Airmo HCHO

 

New instrument for measurement of formaldehyde : Airmo HCHO

1. Why measuring the formaldehyde

The HCHO is part of the COV ozone precursors list as a substance listed by the Directive 2002/3/CE and PAMS (US).
It is danfgerous for health, mainly by inhalation and cutaneous contact in indoor ambient air in the professional environnement. It can cause irritations and the corrosion of mucous membranes and can have carcinogenic effects. Toxicological Index: VME: 500 ppb, VLE: 1000 ppb. Some sources of emission: exhaust gas of motor vehicles, binding materials of wood.

2. Chromatotec’s analyser AirmoHCHO

This instrument which detects and quantifies formaldehyde on-line and in continuous as well as other compounds such as acetaldehyde, methanol and acetone, is articulated around the model airmoVOC: 6 ways valve, 3 phase trap, capillary column, methanisation oven and FID detector.

Permeation oven and tube inside instrument all permits to achieve autocalibration. N2 is the carrier gas. -The minimum of detection is from 1 to 2 ppb of HCHO in ambient air (background pollution, background noises). Measurement range is 1 to 100 ppb with good linearity and without interferents.
Data are displayed and stored on hard disk of the integrated computer thanks to the analyser software “Vistachrom”. Two models are available: one with trap (ppb range ), one with loop (ppm range). Results are available on request
Ref: A13000