Standard for ambient air quality : MCERTS EN 14662-3:2015 and EN-15267-1 and -2 (26 July 2018)
airmoVOC and airTOXIC from Chromatotec are used as reference for the EN 14662-3:2015 norm.
Test was carried out by NPL Laboratory and the MCERTS Certificate was approved by SIRA.
Chromatotec is also European Standard EN 15267 compliant, for the product certification of automated measuring systems (AMS) for monitoring emissions from stationary sources and ambient air quality.
MCERTS Certificate airmoVOC
MCERTS Certificate airTOXIC
Click on link below to download file
NPL Laboratory tests report (10.4 Mb)
IET Buyers’ Guide 2013 article (1.9 Mb)
Related Norms :
-
The MCERTS scheme certifies that the CAMS (Continuous Ambient Air Monitoring System) of a manufacturer complies with the performance criteria of EN 14662-part 3 (Ambient Air Quality) Standard (...)
-
Published in the IET buyer’s guide 2013 edition.
Due to environmental issues, the world of gas analysis is evolving very rapidly.Governments set the rules to limit and control the environmental (...)
Official CNR Norm - airmoBTX (28 October 2010)

Our
airmoBTX1000 has obtained a new certification from The Italian National Research Council (CNR) in July 2007.
Click on link below to download file
CNR norm 2008 - airmoBTX (379 kb)
Related Product :
airmOzone Chinese Certification (18 August 2010)
Chromatotec is pleased to announce that our airmOzone cabinet has recently received another certification ! On August 18th 2010 we received the Pattern Approval Certification according to the Metrology Law of the People’s Republic of China. This continuous product development ensures that we remain ’The Experts in Gas Analysis’.
Click on link below to download file
Chinese certificate (113 kb)
Related Product :
Chinese Certification Awarded (12 April 2010)
Chromatotec is pleased to announce that our airTOXIC PID analyzer has recently received another certification! On March 1st 2010 we received the Pattern Approval Certification according to the Metrology Law of the People’s Republic of China. This continuous product development ensures that we remain ’The Experts in Gas Analysis’.
Click on link below to download file
Chinese certification (128.5 kb)
Related Product :
-
A GC/PID for automatic monitoring of BTEX in air, water and soils
US EPA Test (23 July 2009)
The US EPA has performed a 6 months comparative study of 1,3Butadiene and benzene in ambient air with our airToxic GC analyzer A76022 against the canister method TO-15 at Las Vegas, Nevada.
Real time monitoring with the airToxic GC analyzer allows for the collection of much larger amounts of data than canister sampling at a significant lower overall cost.
The results obtained are similar with both measurement methods.
Click on link below to download file
US EPA report (430.2 kb)
Related Product :
-
A GC/PID for automatic monitoring of BTEX in air, water and soils
1
|
|