Chromatotec expert in gaz analysis

Products

Markets

bullet point

Ambient Air Monitoring (outdoor)

bullet point

Industrial air monitoring (indoor)

bullet point

Pure gases / Gas Manufacturers

bullet point

Natural gases / LPG

bullet point

Emission and CEM

bullet point

Process

Exhibitions

bullet point

POLLUTEC 2010 - France 
Lyon Eurexpo (30 nov. - 3 dec. 2010)

bullet point

Journées Information Eaux 2010 
ENSI Poitiers (28 - 30 Sept. 2010)

bullet point

A&WMA 2010 - ALBERTA, CANADA 
Calgary Telus Convention Centre (22 - 25 June 2010)

bullet point

ACHEMASIA 2010 - CHINA 
Beijing (01 - 04 June 2010)

bullet point

NATURAL GAS ODORIZATION - USA 
Marriott Westchase Hotel Houston, Texas (25 - 26 May, 2010)

bullet point

LES RENDEZ VOUS CARNOT - France 
Espace double mixte - Lyon (5 - 6 May 2010)

bullet point

IRAN OIL SHOW - Iran 
Tehran Permanent Fairground - Tehran (22 - 25 April 2010)

bullet point

ENVIRO ARABIA - Kingdom of Bahrain 
Gulf International Convention & Exhibition Centre - Manama (18 - 21 April 2010)

Conferences & Posters

bullet point

ENVIRO ARABIA - Kingdom of Bahrain 
(18 - 21 April 2010)

bullet point

CERTECH - Symposium Emissions and odours from materials - Belgium 
(7 - 8 October 2009)

airmoTHC

 

airmoTHC CH4 and Non Methane Total Hydro Carbon NMTHC A gas analyser for Hydrocarbon and VOC with flame ionization detection

It is an automated isothermal industrial gas chromatograph dedicated to the analysis of volatile organic compound in air (indoor, outdoor, combustion), industrial hygiene, pure gas like N2/CO2/O2.
 

As a fully automatic instrument, he allows un-attended operation the commissioning 24/24.

  • The injection is made via a loop and heated valve.
  • Trap for concentration of NMTHC in ppb application
  • The separation between CH4 and NMTHC is achieved using a trap back flush with thermodeorption.
  • No oxygen effect

Synergism occurs.

  • A valve regulates carrier gas (hydrogen or Nitrogen or air). The retention time drift is less than 0,3%.
  • The instrument has a flame ionization detector (FID) heated at 150°C.

The Vistachrom software enables the user to visualize and store data on a computer. Furthermore it provides comfortable utilities to recalculate, calibrate and export data and to set-up measurement. The airmoTREND software allows the calculation of retention time, area, mass or concentration profiles.
 

 